F-960 Ripen It! Gas Analyzer

(No reviews yet) Write a Review
$4,875.00
SKU:
2003003
<B>Datasheet</B>:

Frequently Bought Together

Please choose options for all selected products

Ethylene Range is 0-1000 ppm

The F-960 Ripen It! Gas Analyzer quickly and accurately measures ethylene (C2H4), CO2 and O2 to assist with decision making throughout the produce ripening process. All three sensors work together to give you a clear picture of gas concentrations in ripening rooms. 

The Ripen It! is a handheld unit that can easily be transported into ripening rooms or connected to rooms through external ports. Data is conveniently transferred from the device to a network using Bluetooth or the removable 
SD card.

NOTE: Three other models are available.  These have different detection ranges.  Contact us for details.  

Features:

  • Measures C2H4, CO2 and O2
  • Displays results in under 30 seconds
  • Past records stored on the device
  • Handheld and lightweight
  • Battery lasts for 8+ hours
  • Wi-Fi capabilities
  • Display easily viewed in dimly lit environments
  • PolarCept!TM water filter for removing non-ethylene hydrocarbons

Specifications:

  • Sampling Flow Rate: 70mL/min
  • Total Sampling Time: 90 seconds
  • Data Saving: Automated, 1 second intervals
  • Display: Sunlight visible transflective LCD
  • Operating Environment: 0°-50° C (0-90 % humidity non-condensing)
  • Operating Atmospheric Pressure: 500-1200mbar
  • Dimensions: 18 cm x 13.5 cm x 5.5 cm
  • Weight: 0.95 kg
  • Enclosure: Powder coated aluminum
  • Battery Life: 8.5 hours
  • Power Source: Removable rechargeable lithium-ion battery
  • PC Interface: USB and WI-FI SD card + Bluetooth
  • Data Recorded with Each Measurement: Ethylene, CO2 and O2 concentrations, date, time, RH, GPS location
  • C2H4 Sensor Specifications 
    • Sensor Type: Electrochemical
    • Range: 0-1000ppm
    • Resolution: 1 ppm
    • Accuracy (absolute): ±2 ppm
    • Accuracy (relative): ±5%
    • Lower Detection Limit: 2 ppm
    • Offset calibration: Weekly
    • Span calibration: 3 months
    • Sensor is replaceable by user
    • Sensor lifetime: 1 year
  • CO2 Sensor Specifications
    • Sensor Type: Infrared Sensor, Pyroelectric detector
    • Range: 0-100%
    • Resolution: 0.01%
    • Accuracy (absolute): ±0.01%
    • Accuracy (relative): ±3%
    • Lower Detection Limit: 0.01%
    • Offset calibration: Weekly
    • Span calibration: 12 months
    • Sensor is not replaceable by user
    • Sensor lifetime: 5 years
  • O2 Sensor Specifications
    • Sensor Type: Electrochemical
    • Range: 0-100%
    • Resolution: 0.1%
    • Accuracy (absolute): ±0.10%
    • Accuracy (relative): ±2%
    • Lower Detection Limit: 0.10%
    • Offset calibration: Weekly
    • Span calibration: 6 months
    • Sensor is replaceable by user
    • Sensor lifetime: 2 years

Note: above specifications are for continuous mode measurement; for headspace/trigger mode measuring, download the detailed specifications sheet.

 

Datasheet: